Datacentre Cooling.

The predictable solution for an unpredictable environment

EcoBreeze Air Economizers
EcoBreeze Air EconomizersModular, Indirect Air Economizer for Medium to Large datacentres

Air-side economizer that maximizes energy efficiency and reduces cooling costs by up to 75% EcoBreeze™ is a pre-engineered and tested product designed to meet the expanding requirements for datacentre efficiency. EcoBreeze provides multiple modes of economization to maximize energy efficiency during the year. Additionally, it can utilize a supplemental mechanical cooling circuit to maintain the datacentre cooling set point on the worst of ambient conditions. Available in a 20ft (6m) or a 40ft (12m) ISO frame, the modular design allows for scalability in 50kW increments up to 400kW of total cooling capacity. The intelligent controls and redundant components of EcoBreeze maintain reliability and availability during constantly changing ambient conditions.

InRow Chilled Water
InRow Chilled WaterClose-coupled, chilled water cooling for medium to large datacentres.

The InRow Chilled Water product design closely couples the cooling with the IT heat load. This design prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available with and without humidity control, these products are designed to meet the diverse requirements for medium to large datacentres. Datacentre operators looking to improve efficiency or deploy high density servers will benefit from the modular design of the InRow Chilled Water products. The intelligent controls of the InRow Chilled Water products actively adjust fan speed and chilled water flow to match the IT heat load to maximize efficiency and address the dynamic demands of today’s IT environments.

InRow Direct Expansion
InRow Direct ExpansionClose-coupled, air, water, and glycol cooling for closets, server rooms, and datacentres. The predictable solution for an unpredictable environment.

The InRow Direct Expansion product design closely couples the cooling with the IT heat load. This design prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available in self-contained, fluid cooled, and air-cooled configurations with or without humidity control, these products meet the diverse requirements for closets, server rooms, and datacentres. IT operators looking to improve efficiency or deploy higher density equipment will benefit from the modular design of the InRow Direct Expansion products. The intelligent controls of the InRow Direct Expansion products actively adjust fan speed and refrigerant flow to match the IT heat load to maximize efficiency and address the dynamic demands of today’s IT environments.

InRow Pumped Refrigerant
InRow Pumped RefrigerantClose-coupled, pumped refrigerant cooling for medium to large datacentr. The predictable solution for an unpredictable environment.

The InRow Pumped Refrigerant product design closely couples the cooling with the IT heat load. This design prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available in overhead or floor mounted configurations, these products are designed to reduce power and whitespace consumption without introducing chilled water next to IT equipment. Datacentre operators looking to improve efficiency or deploy high density servers will benefit from the modular design of the InRow Pumped Refrigerant products. The intelligent controls of the InRow Pumped Refrigerant products actively adjust fan speed and refrigerant flow, with no minimum loading, to match the IT heat load to maximize efficiency and address the dynamic demands of today’s IT environments.

Rack Air Distribution
Rack Air DistributionAir distribution for power dense racks and low pressure area. Rapidly deployable solutions to quickly address hot spots in existing IT environments.

Rack-based products are specifically integrated in or on individual rack enclosures. Rack mounted air distribution products solve inadequate air distribution problems within a rack enclosure. These fan products work with existing cooling products to either provide cool air to or remove heat from the rack enclosure. These hot spot problem solvers ensure uniform inlet temperatures to the IT equipment.

Thermal Containment
Thermal ContainmentAir containment systems designed to maximize cooling predictability, capacity, and efficiency The most efficient way to cool the IT environment.

Aisle Containment products maximize the effectiveness of InRow cooling solutions for low to high density racked IT loads. Available in rack or aisle level configurations, these products are designed to completely separate the supply and return air paths of the IT equipment. Ideal for any IT environment, the air separation ensures the warmest possible air is being returned to the InRow cooling units, which further increases the efficiency, capacity, and predictability of the cooling system. Aisle containment is available for 300mm, 600mm, 750mm wide NetShelter Racks, UPS/PDU, and InRow Cooling products. Front containment can also be added to the rack configuration for additional isolation and noise dampening.

Condensers
Specifically engineered heat rejection for row and room cooling products. System matched to maximize the availability of Row and Room cooling products.

APC air-cooled condensers support Row and Room cooling products to provide a complete solution for small to medium datacentres. Available with fixed and variable speed fans, these products support a wide range of applications.

Fluid Coolers
Fluid CoolersHeat removal designed to use water or glycol for row and room cooling products. System matched to maximize the availability of Row and Room cooling products.

APC fluid coolers support Row and Room cooling products, including support of economizers, to provide a complete solution for small to medium datacentres. These products offer the flexibility to support a wide range of applications.